Local display Type TD 8250 for sensors VZ...

Product description

Description

Local display Type TD 8250 for sensors VZ...

The SIKA TD 8250 local display is simply fitted between the connector plug and the cable socket of the SIKA VZ... positive
displacement flow sensor. It is programmable via two buttons which are located behind the front panel. It can be set to display either the actual flow rate or the total volume (counter function), as required. The TD 8250 is available in three different output signal versions:

  • Pulse output (2-channel, depending on flow sensor)
  • Analogue output 0(4)...20 mA
  • Two alarm contacts

It is also easy to retrofit onto existing flow sensors. To do this, merely remove the amplifier board from the cable socket.

 

 

Technical features

Technical features

 
Signal input Pulse signal from flow sensor
Programming Via 2 buttons, data retention on power failure
Display Four-digit LED display, red, 7.6 mm high
Power supply 18...28 VDC, optional 10...19 VDC
Output signals

 
Pulse output (2-channel, depending on flow sensor)
or analogue output 0(4)...20 mA
or 2 alarm contacts max. 24 VDC / 1 A
Housing Aluminium, 60 x 35 x 60 (W x H x D) without plug connector
Degree of protection EN 60529 IP65
Electrical connection Plug connector EN 175301-803-A, 4-pin

 

 

 