SIKA
HomeProductsDistribution PartnersContactsServiceAbout Us
SIKA
deutsch english francais
Flow monitoring instrument TU 7050
Flow monitoring instrument TU 7050

Flow monitoring instrument TU 7050
Complete monitoring - safely!

Switching transmitter for Turbotron flow sensors - Remote mount version

The TU 7050 is a two channel switching transmitter for use with all Turbotron Series flow sensors.

Pulse signals from flow sensors operate a dual set of galvanically insulated, dry contacts which in turn, may be used to activate alarms.

Set point adjustments are allowed, in up to 16 increments, via a pair of rotary switches set into the module’s front panel.

The rear panel contains the DIN rail mounting assembly.

Two selectable modes are available:

Mode A
Two identical turbine flow sensors operate one set point each.

Mode B
One turbine flow sensor operates a pair of alarm set points
(pre-alarm & main alarm or min & max).

Signal input
Frequency signals of up to two identical flow sensors 
VT...15
VT...25
VT...40

Set point range
VT...15  0,5...29,5 l/min
VT...25     3...100 l/min
VT...40     7...275 l/min

Outputs
Two independent, potential free c/o contacts